Guide to Shop Underground Cable Locator in NOYAFA

Guide to Shop Underground Cable Locator in NOYAFA

2021-10-22
NOYAFA
50

On this page, you can find quality content focused on underground cable locator. You can also get the latest products and articles that are related to underground cable locator for free. If you have any questions or want to get more information on underground cable locator, please feel free to contact us.

SHENZHEN NOYAFA ELECTRONIC CO.,LIMITED specializes in the production of underground cable locator. After years of improvement in the production process, it has shown the outstanding performance. The raw materials are high quality and sourced from premium suppliers. Its service life is highly guaranteed by the strict test procedure which is in line with international standard. Meticulous attention is put into the whole production of the product, which makes sure that it will have a complete life cycle. All these thoughtful measures lead to huge growth prospects.A brand isn't just a company name and logo, but the soul of the company. We built the brand NOYAFA representing our emotions and images that people associate with us. To facilitate target audience's searching process online, we have invested heavily into creating new content regularly to increase the chances of being found online. We have established our official account on Facebook, Twitter, and so on. We believe that social media is a kind of platform with power. Though this channel, people can know our updated dynamics and be more familiar with us.At Best Cable Tester Supplier in China _ Noyafa, we know each application of underground cable locator is different because every customer is unique. Our customized services address customers' specific needs to ensure continuous reliability, efficiency and cost-effective operations.
more products
recommended articles
Info Center News
Introduction of Test Composition of Live Cable Fault Tester
Introduction of Test Composition of Live Cable Fault Tester
Cable fault tester is a commonly used cable fault detection equipment. This equipment is used with a variety of cable fault detection. Its stable performance and accurate detection make the cable fault detection more comprehensive. The work efficiency of inspectors has been greatly improved. Today we mainly explore the composition of live cable fault tester. Test composition of live cable fault tester: 1. Live cable fault tester is composed of the following parts: 1. Instrument host: cable fault flashover tester, referred to as flashover tester for short. Cable path test signal source, referred to as path tester. Cable fault point / path meter receiver, referred to as point meter. 2. High voltage accessories: high voltage pulse capacitor. The utility model relates to an AC / DC dual-purpose high-voltage test transformer. High voltage test transformer operation box. 2、 The test functions of the cable fault tester mainly include: 1. Purpose: it is suitable for low resistance fault test, short circuit fault test, open circuit fault test, high resistance leakage fault test and high resistance flashover fault test of various power cables with different sections and media, high frequency coaxial cables, municipal cables, street lamp cables, ground buried wires, etc. Specifically, there are the following types: (1) testable cables are equivalent according to voltage: low voltage cables and high voltage cables. (2) Testable cables can be divided into: power transmission cables; Control cable; Street lamp cable. (3) The testable cables can be divided into: directly buried cables, cables laid in cable trenches, overhead cables and more than two parallel directly buried low-voltage wires. (4) Testable cables can be divided into: short circuit fault; Phase failure; Low resistance fault; High resistance leakage fault; High resistance flashover fault is described in detail after fault classification. (5) If there is a cable identifier, we can find the cable we are looking for from multiple cables buried in the cable trench, that is, the cable identifier. (6) Both fault test and cable identification are conducted for power-off cables, and fault test cannot be conducted for live running cables. 3、 Introduction to the test principle of cable fault tester: 1. The host of this set of instrument is a host, which is mainly used for cable fault test. 2. It is a rough measuring instrument for cable fault distance, which can measure the approximate distance from the fault point to the cable test end face. 3. The lightning meter can measure the cable length and the propagation velocity of electromagnetic wave in the cable. The test principle of lightning meter is radar reflection method, also known as pulse reflection method. Single end test distance of lightning meter: 15km. Minimum test distance (blind area) of lightning meter: 15-20m. 4. Measurement error of cable fault tester: rough measurement error & plusmn; 1%, system (point) error & plusmn; 0.2m. In short, after accurately determining the fault point, dig a pit to find the fault point. 5. The principle of cable fault detector for finding cable path is to add electromagnetic wave signal to the tested cable and receive the signal of finding cable path through the pointing instrument. The minimum characteristic of receiving electromagnetic signal on the ground directly above the cable is used to determine the buried position of the cable.
Dry Goods Sharing Brought by Power Cable Pathfinder Manufacturers
Dry Goods Sharing Brought by Power Cable Pathfinder Manufacturers
It is generally believed that wear and aging caused by daily time accumulation and sudden faults caused by external factors will affect the use of cables. Both of them will cause fault trip, interrupt power supply operation, and cause power grid paralysis in serious cases. Among these factors, the time accumulation factor can be controlled artificially, resulting in a very small probability of failure, while the external environmental meteorological factors can not be controlled, resulting in a very high probability of failure and great destructive power. Below, the manufacturer of power cable Pathfinder summarizes this problem. 1、 Lightning strike power cable Pathfinder manufacturers believe that lightning weather is common in rainy season and has great randomness. A large number of transmission lines erected in the field have the characteristics of large tower span and large height difference, which makes the lightning resistance level of the line relatively poor and vulnerable to lightning. In harsh terrain, there are many single circuit lines, and there is no shielding and shunt protection provided by parallel lines, which increases the incidence of lightning accidents. Lightning trip accounts for the largest proportion of transmission line faults, and the lower the voltage level, the higher the probability of lightning fault. In order to reduce the probability of lightning accidents on transmission lines, it is necessary to prevent flashover, arc building, direct strike and line interruption. The following protective measures shall be taken: 1. Erect lightning conductor. 2. Add coupling ground wire. 3. Reduce the impact grounding resistance of iron tower. 4. Neutral point indirect grounding system is adopted. 5. Strengthen the line insulation level. 6. Automatic reclosing shall be installed. 7. Install tubular lightning arrester. 2、 Typhoon weather is accompanied by strong wind and rainstorm, and accidents such as conductor galloping, wind deviation, line breaking and tower falling will occur on the transmission line. Broken lines and inverted towers are prone to North-South disconnection. With the increase of the designed wind speed of the power system on the transmission line, the probability of line breaking and tower falling accidents decreases, but the probability of accidents caused by violent swing of conductors, wind bias discharge and damage of floating objects is high. For the vibration lines with low wind speed, most of the lines can be controlled by installing anti vibration devices. In case of strong wind speed, the following measures can be taken: 1. Add anti vibration hammer and heavy hammer device to increase the vertical load carrying capacity of the transmission line and reduce the left and right swing amplitude of the line. 2. Install damping wires and armour rods, increase the number of split wires, strengthen conductors, and ensure the safe distance between conductors and iron tower. 3. The suspension mode of V-shaped insulator string is adopted to enhance the insulator resistance to lateral drift with the wind and reduce the wind deflection swing angle of insulator string. 4. When designing tower type and erecting transmission line, it is considered to leave a large distance between conductors, move down the hanging point, or lengthen and widen the cross arm. 3、 Mountain fire is caused by high temperature, human factors and other factors, which makes the air in the state of high temperature and low humidity for a long time. It is located in the mountainous terrain, between the transmission line crossing forest vegetation and the earth or between phase lines. Due to the rise of thermal dissociation of air particles, the increase of charged charge and the acceleration of particle movement The occurrence of line flashover tripping due to the formation of conductive channel accounts for 90%%uff0c of mountain fire tripping, which is the main cause of mountain fire tripping. It also includes the burning of line insulation at high temperature and the discharge of conductor to tower. In view of the mountain fire phenomenon, we should start with the fire prevention measures to reduce the incidence of mountain fire: 1. Control the height, quantity and type of trees near the tower base. 2. Emergency response measures shall be established, and safety passages with sufficient length and width shall be reserved. 3. The line protection system is reliable and sensitive. 4. Establish a real-time monitoring system and improve the monitoring effect; ⑤ Increase line inspection and eliminate hidden dangers by season, time period and weather conditions.
Principle of Cable Fault Tester
Principle of Cable Fault Tester
At present, the cable fault tester based on impulse flashover method used by the majority of users of power cable fault tester can easily roughly measure the distance of fault point with rangefinder when solving low resistance fault and dead ground fault of low-voltage cable (the distance test of such fault point does not need high-voltage discharge equipment, but uses low-voltage pulse method), However, the method of lighting fire, discharging and listening to sound is still used to locate the fault point. At the same time, the Pathfinder and fixed-point instrument of this kind of instrument are separated, which makes it impossible to synchronize the fixed-point when finding the path, and the fixed-point often deviates from the path. Moreover, due to the limitations of the principle, it is difficult to find the accurate path of the cable when finding the cable path, It is generally between 1-2 meters wide. Starting from practicability, hn-a10 series cable fault locator just makes up for the above defects. It can test the fault point location, buried depth and path synchronization of cable. The indication of fault, path and buried depth of the instrument is very intuitive, without technical analysis and completely independent of the operator's experience. It makes the originally tedious fault test work become a relaxed and interesting thing. Therefore, if the majority of impulse lightning cable tester users have another ht-tc cable fault locator and the original distance finder, they can form a set of perfect low-voltage cable fault tester. At the same time, the low resistance and open circuit faults of high-voltage cables can also be quickly fixed, and the work efficiency can be improved several times. In fact, the majority of power consuming enterprises and units rarely contact the maintenance of high-voltage cables in daily production, because the maintenance right of high-voltage cables is generally specially maintained by the prefecture and municipal power departments. The number of low-voltage cables is far greater than that of high-voltage cables. For enterprises, factories and mining units, residential areas, scientific research institutes, more developed towns and villages, colleges and universities, some small and medium-sized cities and county-level power supply bureaus, the solution of low-voltage cable faults is what they are most concerned about. In fact, what low-voltage cable users need is a tool tester with simple operation, convenient carrying, strong practicability, low price and suitable for field operation. Because the insulation strength of low-voltage cable is low, if the method of ignition and discharge is used to test the fault of low-voltage cable, we find that this method sometimes causes secondary fault. More seriously, after ignition and discharge, the service life of the cable will be reduced and the fault incidence will be increased, which will seriously affect the normal power supply and production.
Working Principle of High Voltage Cable Fault Locator
Working Principle of High Voltage Cable Fault Locator
High voltage cable fault locator is a comprehensive cable fault detection instrument, which can test the high resistance flashover fault, high and low resistance grounding, short circuit, cable disconnection, poor contact and other faults of the cable. The cable fault locator is equipped with an acoustic pointing instrument, which can be used to accurately determine the accurate position of the fault point. It is especially suitable for testing power cables and communication cables of various models and different levels of voltage. The high voltage cable fault locator consists of three main parts: power cable fault tester host, cable fault locator and cable path tester. The host of the cable fault tester is used to measure the nature and total length of the cable fault and the approximate position between the cable fault point and the test end. The cable fault locator determines the exact location of the cable fault point based on the approximate location of the cable fault point determined by the host of the cable fault tester. For buried cables with unknown direction, a pathfinder shall be used to determine the underground direction of the cable. The basic method of power cable fault test is to apply high-voltage pulse to the fault power cable to produce breakdown at the cable fault point. When the cable fault breakdown point discharges, it generates electromagnetic wave and sound at the same time. Dear customers: Hello, our company is a high-quality development group with strong technical force, providing users with high-quality products, complete solutions and superior technical services. The main products are street lamp cable fault tester, underground pipeline detector, cable identification instrument, etc. The enterprise adheres to the tenet of building a business in good faith, keeping the business with quality and developing the business with enterprising. It continues to climb new peaks with a firmer pace and make contributions to the national automation industry. New and old customers are welcome to buy their favorite products at ease. We will serve you wholeheartedly!
Cable Fault Detector_ Medical Devices Will Maintain High Growth in the Coming Years
Cable Fault Detector_ Medical Devices Will Maintain High Growth in the Coming Years
The medical and pharmaceutical chamber of Commerce of the all China Federation of industry and Commerce established the medical device Professional Committee yesterday and issued the 2012 analysis statement of the medical device industry. The statement shows that the dependence of some domestic high-end medical equipment markets on imports has decreased slowly last year. According to the deployment of deepening medical reform and the spirit of the 2012 national health work conference, the statement implies that China's medical device industry achieved a total sales revenue of 68.7 billion yuan in the first half of 2012, a year-on-year increase of 20.27%, The overall requirements of this year's work are: closely focus on the central task of deepening medical reform. It is predicted that China's medical devices will maintain rapid growth in the next 5-10 years, and the industry as a whole will maintain a growth rate of more than 20%. Among them, the focus is on food safety, occupational disease prevention and drinking water safety. According to the statistics of the statement, at present, although the number of medical device enterprises across the country has reached more than 14000, the competition pattern of the medical device industry is relatively scattered. In 2012, the food safety and health supervision of the health system should pay close attention to the following aspects: first, do a good job in food safety, More than 80% of them are small and medium-sized enterprises. The scale of enterprises is small, and there are problems such as insufficient R & D investment and weak technical ability. Because of fierce competition and low profitability, enterprises can only produce medium and low-end products or provide spare parts for foreign enterprises. " The head of the association hinted.
A Brief Guide to Selecting Cable Length Testers
A Brief Guide to Selecting Cable Length Testers
The LinkRunner LTRA offers a variety of cable testing techniques, including TDR, wiremapping, office identification and toning. The LTRA is designed to help troubleshoot wiring problems such as excessive cable routing, cable breaks, wall panels, patch panels, etc. It uses a combination of TDR and resistance measurements to map the wire, measure cable length and detect anomalies such as short, open or split pairs.The LRAT can measure an accurate cable length of 100 m or less with an accuracy of plus or minus 2 m. It can also be used to test terminated cables connected to an internal cable mapping port (WMAP) or an external cable identification accessory, as well as undermined and open cables. For pre-assembled and non-assembled cables, the fault detection is accurate to within 0.8 m of the error distance.This tester is a wiremapper that checks connections for CAT 5E / 6 certification, but can also test performance at higher frequencies. The threshold for the low voltage resistance is set insulated for 5 mO to a contact resistance of 0.1 O. This is measured with an embedded resistance at 100 O (1 mO x 1) to achieve an accuracy of less than -0.1 o (5 mO).In fact, certification testers can test wire diagrams, length attenuation, and crosstalk from one connection to another, helping you troubleshoot and save the results in a printed report for the customer. Cable certification testers are automated, so it's so easy to get a pass or fail at the touch of a button. Installers use certification testers to test cables that are being laid.There are a large number of cable testers on the market today, which means that there may be the right device for your purposes. To help you find the best network cable tester for your use I have compiled a list of test products that work well. As someone with extensive experience as an electrician, I can say that the Elegiant Network Cable Tester is the best tool for testing cable connections.I came across the Elegiant Network Cable Tester while working on establishing a LAN connection for a local company. As a consumer, I used the handheld network cable tester with RJ11, RJ12, RJ45 for the Cat 3 types Cat 5E, Cat 6 and Cat 6A. The broad compatibility of the device does not complicate your work in the analysis of cable connections.Cable Prowler (tm) provides complete cable testing for all categories of network, coaxial and telephone cables. Selecting, selecting and purchasing a suitable network cable tester is a complicated and challenging task. Purchasing the right network cable tester can save you a lot of inconvenience and trouble.Includes low-voltage and high-voltage subsystems, HVX-compliant automation, enabling extended testing of insulation resistance, dielectric breakthrough, Zener diode breakthrough, voltage upgrade, 4-wire measurements, and advanced measurements. With the changing landscape of corporate cabling, there is a demand for testing equipment you can rely on. Hopefully this article has helped you choose the best network cable tester for your profession and field of work.Advanced measurement options provide increased x5 / 2 wire resistance resolution for backplane, complex networks, capacitors, wire pairs, capacitors, twist pairs, and cable length testing. Copper remains the first choice for telephone data and video lines. Integrated Intellitone digital / analog tones are located on the cable or wire pair in the active network.It is an expensive device that requires trained operators and many failures due to problems with the wirecard. Other crews use low-cost cable ties to ensure the connections are correct before the certification tester is turned on. Instead of letting the crew find and fix their own wiremap problems, tests and fixes can be made before the cable is installed, and tester costs are not wasted on simple problems.
Does a Network Cable Tester Detect Damage to the Cable?
Does a Network Cable Tester Detect Damage to the Cable?
They are really just meant to see if it's cut or not. Network switches will keep statistics on lines which may indicate some type of deterioration1. how to recover a lost security key using a lexsys router?If you have a machine connected by cable you are in luck. If not, connect your laptop via Ethernet cable to one of the numbered ports on the back of the router. Using the browser of your choice put in 192.168.1.1 in the address field. Unless you have changed it, that is the address of the linksys router. This will bring up a web page from the router. If it asks for an ID/password if you have changed it you will need it to go further. If you have not changed it then the ID is left blank and the password is "admin". Go to Wireless tab, select Security tab and the encryption code (password) will pop up. If is is all stars click on the box to show letters. Now, if you have just forgotten all of the stuff that has changed you will need to reset the router. There is a little button on the back, recessed a little. With the power connected, using a ballpoint pen tip, push in the button and hold it for 30 seconds. While still holding the button, remove the power plug from the back of the router and keep the button pushed in for another 30 seconds. Then, with the button still pushed in plug the power back in, keeping the button depressed for a last 30 seconds. Then release the button. The router will restart with factory settings. After the reset the router SSID will be "linksys" and it will have no security (password) required. You need to access the router now and set it up from scratch.2. cable tv is too expensive?great place to go when bored - work. TV does not pay u so turn it off. people who use less TV earn more $$$. if u must, google TV antennas for one that will work in your areas. rabbit ears do not work in many places.3. 15 Pin Serial Cable?A couple of our earlier generation terminal concentrator units ran on an RS-422 loop that used DB-15 connectors and cabling4. Broken CB Antenna CABLE ?typically, it is best to replace the cable. if that's not a viable option, then go to a CB shop or Radio Shack and get 2 PL259's that are the correct size for your coax, and a PL258 double female connector. repair the 2 coax ends via the instructions, and then connect to the PL258 use black tape (preferably stretch & seal tape) to completely cover the connectors and at least 2" past both connectors up on the coax, to keep water out re-check SWRs5. What Is The Main difference Between Cat 5e Ethernet cable and Cat 6 Cable Ethernet Cable?Let's say you want to play Warcraft with your buddies. A high-speed internet is what you would require for an uninterrupted gaming experience. You can either go for a Wi-Fi networking or a wired network. No doubt, Wi-Fi provides a convenient way to connect the computers at home without any unnecessary hassle of wires. But then, it is also slow and unreliable at times. A wired network, on the contrary, will enable a high-speed network for online gaming, video streaming, file sharing, and much more. Before opting for a completely wired network for your home, you should know about the different cables available in the market. Knowing which Ethernet cable to use can enhance your gaming experience. There are different kinds of network cords that can solve your purpose. The most popular ones include Cat5, Cat5e Cable and Cat 6 Cable. Each of them has its own specific qualities. However, you must select the one that best fits your purpose. All of these cables might look similar from outside but they are internally different. If you look at the text printed on the cable, you'll get to know what type it is. Here is a list of what all you need to know to select the perfect cable for your home network. Cat5: "Old and Slow"Cat5 is oldest of all the network cables. It is made to handle 10/100 Mbps speed, which means it is comparatively slow and less responsive. These cables are old and obsolete. You probably won't find them at a store but if you have an old modem, you might search for one. Cat5e: "Improved and Faster"It is the most used network cable. Cat5e Cable is better at keeping signals in different circuits or channels from interfering with each other. A much-improved Cat5e is made to handle 1000Mb speed, so it is faster than Cat 5 and provides a better networking experience. It is, currently, the most commonly used cable in new installations.Cat6: "Even Faster"Next to Cat5e is a Cat6 cable. It is way faster and much improved. This networking cord is made to support 10 Gigabit speed of Ethernet, which is huge. You probably don't have this high-speed network at your home. This cable would not make much of a difference with the speeds that we get at present. But if you are going for a new one, you might as well go for Cat6 as it is the best of the lot. What Is The Main difference Between Cat 5e Ethernet cable and Cat 6 Cable Ethernet Cable?
How Does the Power Cable Fault Tester Detect the Fault Point
How Does the Power Cable Fault Tester Detect the Fault Point
How to detect the fault point of power cable fault tester: it is composed of notebook computer, test system, path signal generator, path signal receiver and positioning instrument. It can complete the two tasks of cable fault test and cable data management. Notebook computer for measurement control, data processing and cable data management. The fault test system can measure the distance between the fault point and the test end at one end of the fault cable, and can also be used to measure the length of the cable and the propagation speed of radio waves in the cable. The path signal generator can generate 15KHz, * large amplitude 30V intermittent sine wave signals for finding cable paths. The path signal receiver is used to receive the path signal, find the cable direction and estimate the buried depth of the cable. The locator is used to locate the fault point. Technical performance of power cable fault tester 1. Fault test system ● it can test various faults of various power cables and open circuit and short circuit faults of communication cables and local telephone cables. ● the speed of radio wave propagation in any cable of known length can be measured. ● test distance: not less than 40km ● system error: less than 0.5m ● sampling frequency: 25MHz ● test blind area: less than 5m ● power supply: AC 220V ± 10% 2. Pathfinder signal generator. ● signal frequency: 15KHz ● oscillation mode: intermittent ● output power: 30W ● power supply: 220V ± 10% 2. Test sensitivity of power cable fault tester: the signal source with 50 Ω internal resistance outputs 300Hz signal, and the input signal of the pointing instrument shall not be greater than 10 when the output is maintained at 2V and the signal-to-noise ratio is better than 20:1 μ V。 ● input impedance: not less than 1.2k Ω. ● use 2 × 2000 Ω headphones. ● working voltage: 9V ± 10%. ● operating ambient temperature: - 10 ℃ 40 ℃
no data
no data
Contact Us
Leave a message
We welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
During 15 years development, Noyafa has become the most famous brand in cable testing industry in China. With excellent production capability, reliable quality, good after-sales service, we get good reputation from customers all over the world.
no data
Contact Person:Lory Liu
Contact Us

+86-0755-27530990

If you have any question, please contact Lorry via

wire@noyafa.com

Add:Wanjing Business Center, #2506 Xinyu Road, Xinqiao, Baoan District, Shenzhen, China

Copyright © 2021 NOYAFA | Sitemap 

chat online
Please message us and we ensure to respond ASAP, what product you intrested in?