SHENZHEN NOYAFA ELECTRONIC CO.,LIMITED puts efforts to develop greener cat5e cable tester in accordance with the product development strategies. We designed it focusing on reducing environmental impacts throughout its life cycle. And in order to reduce the environmental impact on human, we have been working to replace hazardous substances, add anti-allergy and anti-bacterial features to this product.The extraordinary brand and superior quality products are at the heart of our company, and the product development skill is a driving force within the NOYAFA brand. Understanding what product, material or concept will interest consumer is some kind of art or science — a sensibility that we have been developing for decades to promote our brand.Through Best Cable Tester Supplier in China _ Noyafa, we strive to listen and respond to what our customers tell us, understanding their changing needs on the products, such as cat5e cable tester. We promise a fast delivery time and offer efficient logistics services.
more products
recommended articles
Info Center News
How to Quickly Detect the Fault Point of Low Voltage Cable
How to Quickly Detect the Fault Point of Low Voltage Cable
In many years of specific work, people have found that there are many differences between the common faults of high-voltage cables and low-voltage cables. Most of the faults of high-voltage cables are dominated by common faults of operation, and most of them are common faults of high resistance, which can be divided into leakage and flashover; The common faults of cable can only be led, short circuit and open circuit (naturally, high-voltage cable also includes these three conditions). In addition, the cable also has the following characteristics in the whole process of specific application: 1. The laying is blind, and the relative path is not very clear. 2. When laying, it is not buried after filling sand and bricks like high-voltage cables. On the contrary, the buried depth is shallow, which is easy to be damaged by external forces and common faults occur. 3. Cables are generally short, ranging from tens of meters to 500 meters, unlike high-voltage cables, which are usually 500 meters to many kilometers. 4. The compressive strength of the insulating layer is low. When solving common faults and making connectors, the processing technology is relatively simple. 5. Most cables are often burnt and damaged at common fault points. The common fault point is that there is no mark on the surface of the cable, which is very rare. ⒍ the required load changes greatly, and the two colors are usually unbalanced, which is very easy to get hot, resulting in common faults. Considering the above characteristics of the cable and the proposals clearly put forward by many customers and the specific application status of people in each region, the scientific research staff has successfully developed and designed the DW cable fault test mobile phone positioning system: the system software includes two parts: rangefinder and detector. The range finder of hn-213x system software is a completely intelligent system and personalized design scheme. It automatically detects the cable fault point without manual service, analyzes the common fault wave type, and immediately gives the distance between common fault points and common fault characteristics. The rechargeable battery power supply system is selected, which is convenient for field work, small in size, light in weight, easy to use, and does not need all auxiliary machinery and equipment. The cable fault detector of hn-213x system software is an instrument and equipment for simultaneous and accurate positioning and detection of the laying relative path, buried depth and common fault points of directly buried cables. Because it is a mobile phone positioning system for common cable faults based on the magnetic effect of current and the basic principle of step voltage, it mostly considers all standards of cable fault test. This kind of detection system software has many advantages compared with the cable fault detector based on the impulse flash method: 1. A variety of test standards are integrated and the results are mutually certified to clarify the uniqueness of common fault points. 2. Small size, light weight, easy operation by one person, no auxiliary machinery and equipment. 3. The rechargeable battery power supply system is selected, which is suitable for field work without ignition, charge and discharge. 4. The relative path search of cable (which can be clearly in the middle of 30cm), buried depth detection and accurate positioning of common fault points are carried out in the same step with high efficiency. 5. Clarify the common fault points, and the instruments and equipment have visual display information without wave type analysis. ⒍ it will not be harmed by underground conditions (such as bifurcation of cable, bundling, distortion of connector, etc.). Like detecting bombs, it searches common fault points point by point, and the accurate positioning deviation is within more than ten centimeters, which is very accurate. ⒎ it will not be harmed by ground conditions, such as floor tiles, road greening, concrete ground, etc. 8. Check the safety on the spot, there is no risk to the inspector, and there is no secondary damage to the cable. ⒐ high quality and low price are acceptable to ordinary customers. We know that the insulation layer of cable is relatively low. In addition, the electric flow is very large in the whole process of operation, and there are significant characteristics after common faults. The actual classification is as follows: the first kind of common faults: a piece of cable is burned out or a phase is burned out. This kind of common faults lead to the posture of current relay on the distribution box, and the cable is seriously damaged at the common faults. The second type of common fault: short circuit fault of each phase of the cable. Similarly, this type of common fault causes the current relay and voltage relay on the distribution box to be in a bad position, and the cable is also seriously damaged at the common fault point (possibly caused by external force). The third type of common faults: the cable can only be short circuited in one phase, the current relay posture, and the common fault points are slightly damaged but significantly exposed. It may be due to the high voltage of this phase or the quality of the cable. The fourth type of common fault: internal short circuit fault of cable, no mark can be seen on the surface. This kind of common fault is generally caused by the quality of cable, which is relatively rare. Common faults of hn-213x cable can be easily detected by the fusion application of rangefinder and detector in mobile phone positioning system. In addition, the characteristics of different common faults and the length of cable can also be detected separately. The actual situation is as follows: the first type of common faults and the second type of common faults. If the cable is short (less than 500m), the common fault detector can be used to accurately locate the common faults immediately without the cooperation of the distance finder. The common fault points can be identified by stepping in the hand receiver along the relative path (the relative path can be measured while walking). The third type of common fault: because the cable is slightly damaged at the common fault point, the data signal sent by the transmitter leaks less here. When accurately locating the common fault with the detector, the marking scope is narrow. At this time, the distance between the common fault points can be measured with the distance meter, and then the accurate positioning with the detector is also very convenient. The fourth type of common fault: this type of common fault is the most difficult to predict among all cable faults at this stage. At this time, you can use a rangefinder to detect the cable on both sides of the cable, and then compare the detection results with the specific length, so that the common fault point can be defined in a small range (1-3m). At this time, dig the cable and find the problem, Or decisively cut off this section of cable (because the cable is very cheap, the insulation layer is low, and the connector is easy to do), or use a detector to select the audio frequency for accurate positioning in this section, which can also identify the common fault points. At this stage, the cable fault detector based on impulse flashover method, which is applied by many customers of cable fault detector in power engineering, generally can use a distance meter to roughly measure the distance between common fault points when dealing with common faults of low resistance of cable and common faults of dead grounding device (the distance detection of such common fault points does not need high-voltage charging and discharging machinery and equipment, and the bottom pressure single pulse method is used) However, ignition, charging and discharging and listening to sound are still used for accurate positioning of common fault points. In addition, the relative Pathfinder of such instruments and equipment is separated from the designated instrument, which makes it impossible to specify the relative path at the same time when selecting the correct relative path, and usually deviates from the relative path when specifying. Moreover, due to the limitation of the basic principle, the relative Pathfinder of such instruments and equipment finds the relative path of the cable It is impossible to find the exact relative path of the cable when the cable is in the middle of the total width of 1-2m. Considering the applicability, hn-213x cable fault detector just fills the shortcomings of the application. It can accurately locate the common fault points of the cable, detect the buried depth and the relative path smoothly. The instruments and equipment are very vivid in the marking of common faults, relative path and buried depth No need to do technical index analysis or rely on the working experience of the operator. It makes the original complex fault test work become a relaxed and interesting thing. Therefore, many customers of impulse lightning cable tester can form a set of extreme low-voltage cable fault tester if they have another DW cable fault detector and the original distance finder. In addition, the The common faults of low resistance and short circuit of external high-voltage cable can also be specified quickly to improve the efficiency many times.
Cable Tester to Test Your Home Network
Cable Tester to Test Your Home Network
The introduction of cable testerA cable tester is a market expert who looks into a specific product and finds flaws in it. They are usually looking for products that are either faulty or un-performing, so they make sure to find out which product is the most likely to break. Although, their job is not necessarily related to the product itself, but they look for any sort of issues with the basic properties of an item.Tips for cable testerA cable tester is a person who reviews the quality of cables in different locations and makes sure that they meet the standards. They do this by making inspection decisions, often at short deadlines.The most important thing to remember while reviewing cables is that no part of a cable should touch the ground or any of its power sources because doing so can affect the performance and reliability of cables in those places. In addition, when inspecting cables for damage, there should be other requirements as well - for example, according to ISO-IEC 61631-1 (or equivalent) standard, cable manufacturers have to report any kind of deviation from safety standards.How to use cable tester?This page will provide you with information on the best way to use cable testers.In this article we are going to discuss about how to use cable testers and their pros and cons.The specifications of cable testerThe cable tester is a very important part of the electronics system and it's always in high demand. Also, the industry experts are always looking for more information on this subject.The product instructions of cable testerIt is now possible to test cable products, determine the quality of their performances and reviews, without having to physically go inside the box.##Section topic: Movies and television series of the next generationIntroduction: “The new generation” refers to all people born after 1985 and up. The biggest trend in this context is the increase in the number of young viewers who are looking for different kinds of content. This creates a big opportunity for film makers and television producers. For example, recent films such as "Black Panther" have been successful because they capitalized on this trend by making a character who was not like other characters that had appeared before. It seems that there is an opportunity for movie makers to get inspiration from these trends in order to create feature oriented movies. The same applies forThe application of cable testerThe application of a cable tester is a process that an electrician uses to check the wire and cable system in a building or industrial site before the building is occupied.
Introduction to Underground Pipeline Detector
Introduction to Underground Pipeline Detector
Classification of underground pipeline detectors 1. One category is to detect metal pipelines, electric / optical cables and some non-metallic pipelines with metal marker lines by using the principle of electromagnetic induction. This category is referred to as pipeline detectors for short. Advantages: fast detection speed, simple and intuitive, convenient operation and high sensitivity. Disadvantages: (underground pipeline detector) when detecting non-metallic pipelines, non-metallic probes must be used. This method is laborious and needs to invade the interior of the pipeline. 2. The other is to use electromagnetic wave to detect underground pipelines of all materials, which can also be used to find underground buried objects, commonly known as radar, also known as pipeline radar. Advantages: (underground pipeline detector) can detect pipelines of all materials. Disadvantages: high requirements for environment, poor sounding ability (it is difficult to check pipelines with deep buried depth), and high requirements for operator quality and experience. Any instrument is not superior and needs to be used together in order to give full play to their excellence. Traditionally, pipeline detectors only refer to pipeline detectors using the principle of electromagnetic induction, and also use * many instruments. Dear customers: Hello, our company is a high-quality development group with strong technical force to provide users with high-quality products Complete solutions and superior technical service companies. The enterprise adheres to the tenet of building a business in good faith, keeping the business with quality and developing the business with enterprising. It continues to climb new peaks with a firmer pace and make contributions to the national automation industry. New and old customers are welcome to buy their favorite products at ease. We will serve you wholeheartedly!
How Can Screwdriver Organizers Help DIY Technicians?
How Can Screwdriver Organizers Help DIY Technicians?
Most technicians love to spend their time in their workshops. And for them, their screwdrivers are of utmost importance. It is hard to complete any task when you dont have high-quality screwdrivers handy. Screwdrivers are available in a number of sizes and just having them is not enough. You must also take care of them if you want them to last long. Make sure that you keep them safe and secure at all times. What can be better than modular screwdriver organizers to keep your screwdrivers safe, secure, handy, and organized?All your screwdrivers are in one place but still disorganized. You might face this every single day. And this might be resulting in you wasting a lot of time on finding the right sized screwdriver when you are on a job. What can be worse than this is losing some of them! Being a technician, you can afford any of these situations. It is important that you make sure that all your screwdrivers are handy and safe whenever you need them.How to find Suitable Screwdriver Organizers?There can be any reason why you need to buy a screwdriver organizer. A screwdriver organizer comes as a savior for you. It offers a convenient storage solution so that you can keep your screwdrivers in place without any hassle. And that also means that you dont have to worry about losing them again. The best part about investing in good-quality screwdriver organizers is that they allow quick search so that you dont have to waste your time. Why do you need to buy a Screwdriver Organizer?It is not just your screwdrivers that the toolbox organizer will hold. It will also help you in keeping your other precious tools in place. This way you will able to easily find your tools and keep them back in place after use. The screwdriver organizers come with spaces where you can place the screwdrivers easily. With modular screwdriver organizers, you get enough space to keep your long, short, stubby, and every type of screwdriver.Such organizers are not less than a blessing for DIY technicians who have to work using their tools on a daily basis and also for the people who like to do little tasks of their homes on their own. When you have screwdriver organizers, you will be able to save your screwdrivers from scratches and other harms. As the toolbox organizers come with strong magnets, your tools will never be misplaced. You will always them where they were kept. If you are in search of high-quality modular screwdriver organizers, look no further and visit the official website of Toolbox Widget, We have toolbox organizers for all your tools. While you will keep your tools in a toolbox, it is advised that you clean them properly and apply light oil on your tools before keeping them. To find out more about the toolbox organizers that we have in our inventory, give our official website a visit.
What Are the High Voltage Test Transformers_ Use of High Voltage Test Transformer
What Are the High Voltage Test Transformers_ Use of High Voltage Test Transformer
What is a high voltage test transformerHigh voltage tester refers to a kind of transformer that generates high voltage for high voltage test. High voltage test transformer has the characteristics of high voltage, small capacity, short continuous working time, thick insulation layer and usually one end of high voltage winding is grounded.High voltage test transformer is called test transformer for short. The test transformer is generally a step-up transformer. The test transformer uses the power frequency high voltage induced by the secondary side to test the insulation performance of various electrical products and insulating materials. Test transformer is an indispensable electrical equipment for withstand voltage test in the repair of motor, transformer and electrical products. The test transformer is mainly used for power frequency withstand voltage test of electrical products, partial discharge measurement, thermal stability test of insulating medium, etc; For medium and high frequency electrical equipment, special frequency test transformers can also be used for withstand voltage test and measurement of relevant electrical parameters.The primary and secondary windings of the test transformer have a large voltage ratio. The primary voltage is 0.4kV, 3KV, 6kV and 10kV. The secondary voltage can be made into 100 2000kv or higher, and the capacity can be 3 9000kva. For the field test of power equipment, the light test transformer is generally used; 50kV step-up test transformer is used for withstand voltage test of 6kV, 10kV transformers and other power equipment; For the withstand voltage test of high voltage, ultra-high voltage transformers and other power equipment with voltage level above 35kV, ultra-high voltage test transformers greater than 5 times the primary rated voltage of the tested equipment, such as step-up test transformers of 500kV, 700kv, 800kV and certain capacity level.Characteristics of high voltage test transformer1) High voltage: the primary voltage of the test transformer is 220V or 380V, but the secondary voltage of a single test transformer often reaches thousands to tens of thousands of volts. The test transformer with secondary voltage exceeding 750kV usually adopts multiple cascade structures.2) Small current: the rated current of the test transformer is actually the capacitive current of the tested object, so it is generally less than 1a. However, the secondary current of the test transformer used for cable and large motor test, external insulation pollution test, line corona test and other projects can reach several amps.3) Short working time: due to the short withstand voltage time of the tested product, the test transformer is generally 0.5h or 1H short-time working system except for external insulation pollution test, line corona test and cable test.4) The test transformers are generally single-phase and indoor devices (some are also made into outdoor devices): they are oil immersed self cooling structure, the winding insulation layer is thick, and one end of the high-voltage winding is usually grounded.5) The insulation level of the head and end of the secondary winding of the test transformer is different: the head end is high potential, and the end is directly grounded or grounded through an ammeter.6) High requirements for design and manufacturing process: due to the high working voltage, the insulation structure has a decisive impact on the overall size of the test transformer. Vacuum drying is generally required for the body, and vacuum oil injection is required for above 100kV.Classification of high voltage test transformers1) In terms of structure, there are iron shell type and insulated shell type test transformers.2) In terms of power frequency, there are several frequency level test transformers such as power frequency, frequency doubling, intermediate frequency and high frequency.3) According to the voltage level, it can be divided into low voltage, high voltage and ultra-high voltage test transformers.4) According to the use form, it can be divided into light mobile type and fixed type; There are also single use and two or more cascade use test transformers.The test transformer is generally single-phase and indoor devices, which are oil immersed self cooling structure. Because of its high working voltage, its winding insulation layer is thick, and one end of the high-voltage winding is grounded.The specific structural types of the test transformer generally include single bushing type, double bushing type and insulating cylinder type.Technical requirements for high voltage test transformer①Output voltage waveform. The output voltage waveform of the test transformer shall be close to the sine wave as far as possible. In order to reduce the voltage waveform distortion caused by the harmonic voltage generated by the harmonic component of no-load current passing through the impedance of voltage regulator and transformer, the magnetic flux density should be selected in the straight line section of core magnetization curve; At the same time, voltage regulating equipment with small waveform distortion shall be selected, and filter device can be added if necessary.② Impedance voltage. The secondary current of the test transformer is generally capacitive current. When the secondary current flows through the impedance of the voltage regulator and the test transformer, the output voltage will exceed the value determined by the voltage ratio. Therefore, the impedance voltage of the test transformer should not be too large, otherwise it may affect the accuracy of the test results and reduce the short-circuit capacity of the test equipment. However, if the impedance voltage is too small, the short-circuit current may increase when the test object breaks down or flashover. The impedance voltage of a single test transformer is generally 4.5 10%, and when multiple series transformers are formed, it can reach 30 40%.What are the high voltage test transformers1) DJ oil immersed high voltage test transformerOil immersed test transformer: large volume, heavy weight, large capacity, convenient maintenance and high maintenance cost in the later stage; Mainstream products.The oil immersed type is filled with 25# transformer oil, and the insulation cooling effect is the best2) GTB dry type high voltage test transformerDry type test transformer: maintenance free, light weight, small volume, inverted and high cost.3) Inflatable high voltage test transformerInflatable test transformer: it needs later maintenance, with good arc extinguishing performance, light weight and danger.The oil immersed type is filled with 25# transformer oil, and the insulation cooling effect is the best; Dry type has small volume and lightest weight, but the voltage is difficult to be high; The inflatable type is filled with SF6 gas.Application and operation method of AC / DC high voltage test transformerDuring the step-up or withstand voltage test of AC / DC high-voltage test transformer, if the following unusual conditions are found, the voltage shall be reduced immediately and the power supply shall be cut off. As of the experiment, the reasons have been found out: ①the pointer of the voltmeter swings greatly; ② The insulation of the invention burns or smokes; ③ There is unusual sound in the test object.Utilization and operation methods of AC / DC high voltage experimental transformer:1. Connect the power supply of the control box (console) and turn on the indicator light.2. Press the start button and the operation indicator light is on (otherwise, the voltage regulator is not in the zero position, please rotate the hand wheel of the voltage regulator to the zero position counterclockwise) indicating that the experimental operation can be stopped.3. Move the hand wheel of the voltage regulator clockwise to make the conditioning rate 2KV / s better, and watch the high-voltage meter rise to the required voltage value. For example, in the process of boosting, when the test object breaks down, short circuit and overcurrent occurs, the overcurrent relay acts to automatically cut off the power supply.4. If the experiment requests overcurrent control, adjust the overcurrent relay to the power supply current value required by the experiment in advance before operation, and the current relay will stop overcurrent protection according to the experiment request.5. While monitoring the high-voltage meter, an external 0.5-level voltmeter can be accepted at the instrument end for monitoring.6. Measure the insulation resistance and check the insulation condition before and after the withstand voltage test.
What Are the Test Steps for Cable Failure
What Are the Test Steps for Cable Failure
The detection of cable fault generally goes through four steps: diagnosis, ranging, path finding and fixed point. 1. Diagnose the nature of cable fault, that is, determine the type and severity of fault, so that testers can suit the remedy to the case and select appropriate cable fault location and fixed-point methods. Measure the fault resistance with a megger and multimeter to determine whether the cable fault is high resistance or low resistance; Flashover or closed fault; Whether it is grounding, short circuit, disconnection, or a mixture of them; Is it single-phase, two-phase or three-phase fault. 2. Ranging cable fault location, also known as rough measurement, uses instruments to determine the fault distance at one end of the cable. The common fault location methods on the site include classical bridge method and modern traveling wave method. Use jcd-971 cable fault locator or cd-71 cable fault locator. 3. Use pd2000 cable path identifier or cd-12 / 22 cable path identifier produced by Zibo Electric Co., Ltd. for path finding. 4. Fault location acoustic magnetic synchronization method: use cd-81 cable fault locator to synchronize with the discharged electromagnetic signal and digitally sample the sound signal, The sound waveform at the moment of discharge is displayed on the LCD screen. The waveform can be maintained continuously for the operator to distinguish carefully, avoiding the disadvantage of transient sound. Moreover, the actual discharge waveform is obviously different from the surrounding noise. More importantly, the sound waveforms of multiple discharges are very similar. When the sound waveforms of multiple discharges are observed to be the same, It can be clearly judged that the discharge sound has been collected. Because the response range of acoustic measurement method is generally very small, when the discharge sound is heard, it is very close to the fault point, generally not more than 5m, or even within 1-2m
Overview of Cable Fault Locator
Overview of Cable Fault Locator
Overview of cable fault locator cable fault locator is a comprehensive cable fault detection instrument. It can test the faults such as high resistance flashover fault, high and low resistance grounding, short circuit, cable disconnection, poor contact and so on. The cable fault locator is equipped with an acoustic pointing instrument, which can be used to accurately determine the * * position of the fault point. It is especially suitable for testing power cables and communication cables of various models and different levels of voltage. Detection mode the cable fault locator adopts a variety of detection modes and applies contemporary * advanced electronic technology achievements. Using computer technology and microelectronics technology, it has the characteristics of high intelligence, complete functions, wide range of use, accurate test, convenient use and so on. The design of locator to detect aircraft cable fault is very important in civil aviation maintenance; According to the characteristics of aircraft cable, a method that can effectively test and diagnose it, low voltage pulse method, is proposed, and an aircraft cable defect detection and positioning device is designed by using single chip microcomputer and CPLD technology; The positioning instrument is mainly composed of three parts: signal acquisition circuit, system control circuit and human-computer interaction circuit; At the same time, two sets of product vibration are adopted, which not only ensures the high-speed signal acquisition, but also meets the low-speed processing of the system. It has the characteristics of low cost, portability and dexterity, accurate test and so on; At the same time, in addition to being applied to aircraft cable maintenance, it can also be further applied to short-distance cable testing and defect detection in telecommunications, power and other departments. Dear customers, the company also has cable recognizer, cable tie tester and underground pipeline detector products. You can call the company's service phone through the website to learn more about the details of the products, Perfect and beautiful service is our pursuit. Welcome new and old customers to buy their favorite products at ease. We will serve you wholeheartedly!
How to Use the Cable Identifier and How to Judge Whether the Cable Is Live
How to Use the Cable Identifier and How to Judge Whether the Cable Is Live
How does the cable identifier judge whether the cable is live? First: why should we judge that the cable is live: as an important instrument of power cable detection instrument, cable identification instrument has been used more and more widely. When there are multiple cables in the cable trench, it is necessary to identify a specific power-off cable, calibrate, move or cut off the cable, and other cables in the cable trench operate live, so the cable identification instrument shall be used for cable identification. Second: easy to use: compared with the cable fault tester, the use of the cable identification instrument is relatively simple. It is easier to use it by reading the instructions. Third: test example: since the cable shielding layer is usually connected to the ground, if other cables are also connected to the public ground in the cable bundle, the black output jack on the generator can be connected to the public ground, The return current is distributed in several cable shielding layers, and the return current is divided into many tributaries, which means that the difference current of the identified cable is large and the useful signal is clear. "Difference" means that the output current and its divided return current are in the same channel. As shown in Figure 4, there are 5 cables in Figure 4. Cable 4 needs to be identified. The "output current" of the cables to be identified is 20A. Assuming that the return current is evenly distributed among the shielding layers of all cables, there should be a return current of 4A in the cable to be measured. The difference in the cable to be identified is: 20A (output) - 4a (return) = 16A (difference). How to use the cable identification instrument I. working method of the cable identification instrument: the transmitter (host) is powered by 220V AC power supply, which is used for the power-off The cable to be identified, plus a fixed period, unipolar DC pulse signal. The output line of the transmitter is connected to the cable core and the grounding point or ground nail. The armor of the cable is disconnected from the earth, and the core is connected to the grounding point or ground nail at the far end. The loop can conduct pulse current, which can be read out by the meter on the receiver of the identifier. The current is determined by the loop resistance, and the loop resistance should be as small as possible. The wiring diagram of the identifier is shown in Figure 2. Note: during field use, if the grounding resistance is too small, the output current of the transmitter will also be large when the output adjustment knob is turned back to zero, and the protection circuit in the transmitter will act (shown as a small fast swing of the meter). At this time, the randomly configured 1 ohm 20W high-power resistor can be connected in series in the transmitter circuit. After the transmitter and receiver start working normally, the voltage induced in the sensor coil is displayed in the receiver header. The pointer swing direction of the header can display the current direction, that is, only the cable with current flowing out, the pointer deflects and swings greatly. This is the cable to be found. For all other cables, only the return current flows, the pointer deflects in the opposite direction and the swing is very small. The output adjustment knob on the receiver can adjust the signal strength. 2、 Wiring mode: 1. Before the test, cut off the tested cable, and the surrounding environment shall be in a safe state. 2. The generator is connected with the tested cable, and the red clip is connected with one or several cores of the identified cable. Connect the black clip to the ground nail. 3. Connect the core wire at the far end of the cable to the ground nail. 4. Disconnect the armor at both ends of the cable from the ground wire. 5. Plug the power cord into the power outlet. 3、 Identify the cable through the loop test. 1. In order to ensure the normal use of the instrument, pay attention to setting the test loop. 2. Connect the red output jack to the core of the cable to be identified, connect the black output jack to the ground, and connect the cable core to the ground at the far end. As shown in Figure 3, 3. The output current flows to the far end in the direction of the arrow in the cable, and all cores of the identified cable can be connected together through the earth return generator to obtain a clearer signal.
no data
Contact Us
Leave a message
We welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
During 15 years development, Noyafa has become the most famous brand in cable testing industry in China. With excellent production capability, reliable quality, good after-sales service, we get good reputation from customers all over the world.
no data
Contact Person:Lory Liu
Contact Us

+86-0755-27530990

If you have any question, please contact Lorry via

wire@noyafa.com

Add:Wanjing Business Center, #2506 Xinyu Road, Xinqiao, Baoan District, Shenzhen, China

Copyright © 2021 NOYAFA | Sitemap 

chat online
Please message us and we ensure to respond ASAP, what product you intrested in?